Optimal Distance between Implants

In a recent article, we discussed the amount of bone needed around the implant on the buccal and palatal/lingual sides for long-term survival. We found that the optimal amount is 2 mm on the buccal side and 1 mm on the palatal/lingual side. The primary data comes from a 2000 publication by Dr. Spray.

Side-by-side comparison showing 2mm versus 1mm bone wall thickness between dental implants with measurement indicators

Optimal thickness of the bone wall on the buccal and palatal/lingual sides. YouTube/ Implantarium/ Rauf Aliyev

In this article, we’ll explore the optimal distance between implants, as well as between an implant and a vital natural tooth. In other words, we’ll explore the rules for positioning implants in the mesiodistal plane.

Three titanium dental implants placed in jawbone showing optimal distance between implants with measurement indicators

The answer is very simple and has long been known:

  • distance between adjacent implants ≥ 3 mm
  • distance from implant to tooth ≥ 1.5 mm

This 3 mm rule between implants is prescribed in all textbooks and was first formulated by Dr. Carl Misch. The distance can be greater, but still within reasonable limits; typically, it’s up to 20 mm, but no less. And it would seem that this article could end here.

But the problem is that most sources simply state these figures, and there is no explanation of why this is so, or what will happen if these rules are deviated from.
Our task is to understand exactly why this is the case and what else we should pay attention to.

Why the 3 mm rule works: Biological aspects of optimal inter-implant spacing

Let’s start with the 1.5 mm rule between a tooth and an implant.

The first publication we will turn to is the book by Dr. Ueli Grunder, “Implants in the Esthetic Zone”. This book features a wonderful illustration where a dotted line indicates a 1.5 mm radius around the implant.

Cross-sectional diagram showing optimal distance between implants and natural teeth with 1. 5mm spacing measurements

Implant placement at different distances from natural teeth within the 1.5 mm zone and beyond. YouTube/ Implantarium/ Rauf Aliyev

The fact is that some marginal bone loss around the implant is inevitable. A crater-like defect is formed, resulting in 1–1.5 mm of bone loss both vertically and horizontally. If the implant is positioned too close to the adjacent tooth, this resorption will also affect the bone around the vital tooth. If the interproximal bone crest supporting the gingival papilla is lost, the gums will recede. Gingival recession is not only unesthetic but can also result in the loss of a vital tooth.

The following illustration is from a textbook edited by Carl Misch and clearly demonstrates the importance of understanding the rules for maintaining a 1.5 mm distance when choosing an implant diameter.

Cbct scans showing optimal distance between implants and adjacent teeth with measurement markers

Rules for selecting and positioning an implant based on the distance to the adjacent tooth. YouTube/ Implantarium/ Rauf Aliyev

This example shows that the missing tooth is tooth 13, a maxillary canine—a fairly large tooth located very close to the adjacent teeth. This position requires an implant with a diameter of at least 4 mm, and preferably 4.2 or 4.5 mm. Slide “B” shows that the distance between teeth 12 and 14 is only 6.95 (7) mm, which is fairly typical for the upper jaw. If we subtract 1.5 + 1.5 = 3 mm from 7 mm, we are left with only 4 mm, meaning only a 4 mm diameter implant can be placed.

The following typical situation involves the restoration of a maxillary first premolar. The root of the adjacent canine is curved, and if a 10 mm long implant is placed straight, it will damage the root. However, at the implant platform level, the 1.5 mm rule is observed.

Comparison showing correct and incorrect angled dental implant positioning to maintain optimal distance between implants and natural tooth roots

Rules for positioning an angled implant to avoid damage to the inclined root. YouTube/ Implantarium/ Rauf Aliyev

Simply changing the implant’s angulation will cause its platform to become dangerously close to the canine. If the dentist doesn’t remember the 1.5 mm rule, problems will arise.

What happens if you break the 3 (1.5) mm rule?

A logical question might arise: what happens if an implant is placed closer than 1.5 mm to a tooth? Sure, there will be some resorption and the papilla will recede—is that really such a big deal, especially if it’s not in the esthetic zone and no one can see the papilla?

But it’s not all about aesthetics; in fact, violating this 1.5 mm safety zone is prohibited for entirely different reasons.

The fact is that the periodontium and the alveolar bone, on the one hand, have tremendous adaptive capacity, but on the other hand, they are very easily damaged, and this damage is often irreversible. More precisely, if the surgeon notices during the drilling stage that they have touched the periodontium of the adjacent tooth and refrains from placing the implant in that osteotomy, there is a good chance of correcting the problem. Of course, pulp vitality monitoring is necessary for 2–3 months; if everything remains vital, then a major problem has been avoided.

Note slide “B.” The image shows a “light contact” between the implant and the tooth root, which led to catastrophic consequences. In such cases, the patient is guaranteed to lose the implant, which will cause discomfort from the very beginning. There will be constant pain and mobility, and eventually, the implant will become loose and fail. But the worst part is that the patient is guaranteed to lose the adjacent tooth as well. Neither pulp extirpation nor periodontal treatment will help—they will only delay the inevitable and cause significant discomfort to the patient. The result will be a massive bone defect at the site of the implant and the lost tooth.

X-ray images showing dental implants placed too close to natural tooth roots resulting in implant failure

Examples of failed implantations due to failure to maintain the required distance between the implant and the tooth root. YouTube/ Implantarium/ Rauf Aliyev

The images above confirm the critical importance of the bone wall between the tooth and the implant. Even ignoring the glaring error seen in slide “D,” problems still arise. For example, slide “E” doesn’t seem so critical at first glance, and the bone wall is present. However, slide “F” reveals a disaster: two implants need to be removed, along with the adjacent tooth.

Why do problems arise when all conditions are met?

Although rare, it does happen that all the rules and recommendations for implant placement are followed, yet problems still arise. Most often, the problem lies in the prosthetic component, as shown in the illustration below. The abutment is over-contoured and too close to the tooth; the bone crest between the tooth and the implant is lost, and with it, the interdental papilla. The result is a situation like in slide “D”—loss of papillae and gingival recession around the implant and adjacent teeth.

Dental implant placement showing 1. 5mm and 3. 5mm depth measurements with bone integration and radiographic views of three implants

Examples of cases where an improperly contoured superstructure near a vital tooth leads to soft tissue problems. YouTube/ Implantarium/ Rauf Aliyev

This soft tissue situation complicates oral hygiene, exposing the tooth cervix, which is not covered by enamel. This leads to cervical root caries, which is very difficult to treat, and ultimately, tooth loss.

How digital technology helps maintain the minimum distance between implants

Almost all implant planning software allows you to set a safety zone around the digital rendering of the implant; see the green line in the illustration below.

Digital dental implant planning showing 93. 0mm measurement with 2mm safety zones marked in pink around two implant positions

Digital models of implants with a marked 2 mm safety zone. YouTube/ Implantarium/ Rauf Aliyev

In this case, a safety zone of 2 mm is set, which more than covers the required 1.5 mm.

This function is also highly convenient for many other applications, such as avoiding penetration of the maxillary sinus, preventing damage to the inferior alveolar nerve, and monitoring the position of the implant relative to other anatomical structures.

Cbct scan showing implant position monitoring relative to alveolar crest walls with color-coded measurements

Monitoring the position of the implant relative to the walls of the alveolar crest. YouTube/ Implantarium/ Rauf Aliyev

What distance should there be between adjacent implants?

A very similar rule applies here, only it’s called the 3 mm rule. If you require a 1.5 mm safety zone from each implant, you get exactly 3 mm. It’s worth noting that this is the MINIMUM distance; we’ll now look at why this is so.

Dental diagram showing 3mm and 4mm spacing measurements between implants for bone crest preservation

Optimal distances between implants to preserve the bone crest and the required height of the interdental papillae. YouTube/ Implantarium/ Rauf Aliyev

This topic has been studied quite extensively. The first to delve deeply into this subject was Dr. Dennis Tarnow. While he focused primarily on the restoration of the esthetic zone, the results of his and his team’s work are valid for all areas of the mouth.

Here is one of the key findings from one of Dr. Tarnow’s major works: The effect of inter-implant distance on the height of inter-implant bone crest.

— If the distance between implants is 3 mm, then you can expect a papilla height of 3.5–4 mm.

In reality, it’s not that much, and practically, it looks like the illustration below. The result is acceptable, but far from ideal.

Dental restoration showing two central incisor implants with 3mm spacing and corresponding radiograph

Esthetic and functional result in the restoration of central incisors (distance between implants is exactly 3 mm). YouTube/ Implantarium/ Rauf Aliyev

The following images show the result when the distance between the implants is only 2 mm. From an esthetic perspective, this is a clear failure, and the patient may complain about the quality of the work.

Esthetic soft tissue defect between anterior teeth from implants placed too close together with radiograph

Esthetic soft tissue defect in the esthetic zone due to placing implants too close together. YouTube/ Implantarium/ Rauf Aliyev

The fact is that papilla formation requires support in the form of a bone crest, which is naturally present between healthy natural teeth. This can only be maintained between implants if there is sufficient distance between them. A minimum of 3 mm is required, and preferably more, within reasonable limits, of course.

Comparison showing gingival papilla formation between dental implants at different inter-implant distances with tissue fill variations

Formation of the gingival papilla between implants with varying inter-implant distances. YouTube/ Implantarium/ Rauf Aliyev

Tarnow also discovered a rather unpleasant fact: no configuration of the bone crest between implants will allow for a papilla height greater than 4 mm. In contrast, with a thick phenotype, the papilla height between healthy teeth can reach up to 7 mm. A solution to these situations may be mucogingival surgery, which can alter the tissue phenotype to some extent.

The table below contains documented data on the condition of bone tissue at different distances between implants.

Data table showing recorded lateral and crestal bone loss measurements in millimeters with mean and standard deviation values

Further research based on Dr. Tarnow’s work confirmed the findings. Therefore, the 3 mm rule between implants is now considered dogma.

Here are the conclusions of Dr. Tarnow’s team from that same 2000 paper:

“This study demonstrates the presence of a lateral component of peri-implant bone loss in addition to the more commonly discussed vertical component. The clinical significance of this phenomenon is that increased crestal bone loss leads to an increased distance between the base of the contact point of adjacent crowns and the bone crest. This may determine the presence or absence of a papilla between two implants, as has previously been reported between two teeth.

Selective use of smaller diameter implants at the implant/abutment interface may be beneficial when placing multiple implants in the esthetic zone to maintain a minimum of 3 mm of bone between them at the implant/abutment level.”

In the context of these findings, the advantage of platform switching becomes clear. We’ll discuss this in more detail later.

Another interesting paper by Dr. Tarnow and his team from 2003 is titled “Vertical Distance from the Crest of Bone to the Height of the Interproximal Papilla Between Adjacent Implants”

This study examined how to predictably achieve papilla formation between two implants. Measurements were taken in various planes, including using a periodontal probe, as shown in the illustration below.

Cross-sectional diagram showing measurement of gingival papilla height between two dental implants with optimal distance

Measuring the height of the gingival papilla between two implants as part of a study by Dr. Dennis Tarnow. YouTube/ Implantarium/ Rauf Aliyev

Let’s not delve into the methodology and go straight to the conclusions:

“Clinicians should exercise extreme caution when placing two implants adjacent to each other in an esthetically demanding area. In most cases, only 2, 3, or 4 mm of soft tissue height (average 3.4 mm) above the inter-implant bone crest can be expected. These results indicate that adjustments to treatment plans may be necessary when esthetics are critical to success.”

Platform switching and inter-implant spacing

Dr. Tarnow did not stop his work, and in 2009 another important publication was released:

“The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants”

Dr. Tarnow, never one to rely solely on dogma, decided to support his colleagues in this study and test the hypothesis that attempted to challenge the 3 mm rule. Here’s what resulted.
It was in the late 2000s that sufficient clinical experience with platform switching emerged. While previously the implant platform and abutment margin formed a single line, with platform switching, there’s a horizontal step that provides more space for the soft tissue attachment to form.

Cross-sectional diagram showing platform switching design with 0. 35mm horizontal offset between implant and abutment interface

An early version of the platform switching system. YouTube/Implantarium/Rauf Aliyev

It was decided to test what would happen if implants were restored with an abutment narrower than the implant platform, and positioned closer than the recommended 3 mm distance.
Like all of Dr. Tarnow’s work, this study was conducted with high quality.

Four panel diagram showing bone crest remodeling patterns at different distances between dental implants with abutments

The dynamics of the bone crest and its changes at different distances between implants. YouTube/ Implantarium/ Rauf Aliyev

A total of 82 adjacent implants (41 pairs) were measured in 37 patients (20 women and 17 men). Of the 41 pairs, 27 were placed in the maxilla and 14 in the mandible. Eleven pairs were placed in the anterior region (from incisors to canines), and 30 pairs were placed in the posterior region (premolars and molars).

The choice of which implants to place 2 mm apart and which to place 3 mm apart was randomized. In several cases, the distance between the platforms was only 1.5 mm.

Dental radiographs showing bone tissue condition between multiple implants at optimal distance

Control radiographs of the interimplant bone tissue condition. YouTube/ Implantarium/ Rauf Aliyev

Once again, we won’t go into detail about the methodology of the study, but rather move straight to the conclusions:

“Platform switching allows for peri-implant bone preservation and better interproximal bone crest retention than traditional implants. Bone preservation provides better soft tissue support and improves the crown-to-implant ratio. In narrow edentulous spaces where implants must be placed less than 3 mm apart (1.5 to 3 mm), bone crest preservation is possible with platform-switched implants.

Because this implant design provides greater coronal bone-to-implant contact, it may be more suitable for the use of short implants and in atrophic areas.”

Platform switching is a sound and highly viable concept. The only question that remains is whether platform switching entirely eliminates the need for the 3 mm rule.

Here, another study by Italian authors from 2010 will help us.

“The relationship between interimplant distances and vascularization of the interimplant bone”

This study was conducted on animals, and it clearly demonstrates what happens when the 3 mm rule from the edge of one implant to the edge of another is not observed.

Naturally, the study had two groups: a control group and a test group. In the control group, the 3 mm rule was followed, while in the test group, the distance was smaller.

After placement, the researchers waited for the implants to integrate, prepared histological sections of the bone tissue, and examined them under a microscope. Specifically, they examined the condition of the vascularization within the bone tissue.

Histological comparison showing bone tissue between dental implants with different spacing distances

Comparison of histological bone tissue samples between implants: on the left, the 3 mm rule is observed; on the right, it is not (the implants are located 2 mm apart). YouTube/ Implantarium/ Rauf Aliyev

Here is a short excerpt from the study:

Purpose: The aim of this study was to evaluate how loaded implants placed 2 or 3 mm apart influence bone vessel organization.

Materials and methods: The implants were placed so that two adjacent implants were 2 mm (group 1) or 3 mm (group 2) distant from each other.

After 12 weeks, the implants were loaded with provisional prostheses, then metallic crowns were placed 4 weeks later.

Both temporary and metallic restorations were made so that the distance between the contact point and the bone crest was 5 mm.

The interimplant bone vasculature of the two groups was studied using scanning electron microscopic images fractal analysis. The fractal dimension (Df) was calculated using the box-counting method.

The results revealed that the vascular pattern in the two groups differed significantly. If the distance was less than 3 mm, the quality of the vascular network deteriorated significantly. The number of collateral vessels was notably reduced, and the vascular network was generally less extensive. This directly impacted bone formation and its subsequent nutritional status.

Results:

The values of the Df for the blood vessels were significantly higher (P<.05) in the specimens of the group 2 (1.969±0.169) than the group 1 (1.556±0.246).

The researchers used a variety of evaluation methods, including electron microscopy. Look at the illustration below to see how drastically different the vascular network is.

Electron microscope images comparing vascular network formation between dental implants at 2mm versus 3mm spacing

Electron microscope images: comparison of the vascular network between implants at a distance of 2 mm and 3 mm. YouTube/ Implantarium/ Rauf Aliyev

Conclusions:
The presence of more blood vessels in the group 2 is another indication that 3 mm is a preferable distance for contiguous implants than the 2 mm distance.

It would seem like only 1 mm, but what a colossal difference.

The distance between implants and the risk of peri-implantitis

There is another interesting publication from French researchers. It is similar in many ways to the previous one, except that this one examined not only blood flow but also the overall condition of all surrounding tissues, with the goal of determining how vascularization and other characteristics of the inter-implant bone influence the risk of peri-implantitis.

“The role of vascularization in the development of peri-implantitis”

Here are the conclusions from this work:
“Blood vessel density was significantly higher in the 3 mm inter-implant distance group compared to the 2 mm group. Furthermore, if the blood supply was already compromised due to other factors (inter-implant distance, age, or edentulous ridge conditions), this also negatively impacted implant osseointegration.”

This is crucial work precisely because peri-implantitis is, unfortunately, not a rare condition. It has extremely serious consequences and is notoriously difficult to treat. Therefore, it is important to remember that every time the safe distance between implants is violated, the risk of peri-implantitis increases.

What happens if the distance between the implants is extremely close?

What happens if the distance between implants is extremely close?

The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10‑year follow‑up and literature review

Here is the introduction taken from this work:

“Between adjacent dental implants, an interimplant distance (IID) of at least 3 mm has been recommended to avoid resorbing the interproximal crestal bone. The effect of a 2 mm IID on crestal bone loss has been investigated but the literature is scarce when it comes to an IID of 1 mm. There is a need to document such clinical situations when they occur and elucidate if such a narrow IID is deleterious or not to the interproximal crest. The present case deals with an IID of 1 mm in the premolar area where, for the first time, the fate of an interimplant crest is reported after a 10-year follow-up.”

As seen in the illustration below, modern implant designs with a rough surface extending all the way to the implant platform were used. The interface is also standard and one of the most common—an internal hexagon.

Preoperative radiograph showing bone loss, postoperative dental implant with crowns, and detailed technical implant specifications

Preoperative and postoperative situation. a) Periapical radiograph taken during the initial clinical examination. Note the radiolucent apical area on the root of tooth #24 and the fractured crown of tooth #25. b) Buccal view of the treated areas after placement of the provisional restorations. The crowns are esthetically pleasing despite the extremely small distance between the implants. c) Characteristics of the implant used to treat this patient. Note the cylindro-conical shape, 24-degree internal conical connection with a hex index, and a built-in platform switch of 0.25 mm. YouTube/ Implantarium/ Rauf Aliyev

Here are several images taken at different stages of the follow-up. The first image shows the situation at the time of delivery of the definitive fixed restorations (3 months after implant placement), and the overall picture looks good so far.

Metal-ceramic crowns on implants with periapical radiograph showing platform switch and inter-implant bone

Delivery of the definitive prostheses 3 months after provisionalization. a) View of the prostheses and marginal gingiva from the buccal aspect. The interproximal papilla fills the embrasure space of the metal-ceramic crowns. b) Periapical radiograph after delivery of the definitive prostheses. Note the platform switch, concave emergence profile abutments, and the immature inter-implant bone. YouTube/ Implantarium/ Rauf Aliyev

The next x-ray was taken 12 months after the implants were placed. Everything looks fine here, too.

Periapical radiograph showing two healed dental implants with corticalized bone between them one year post-surgery

Periapical radiograph one year after surgery. Corticalization of the inter-implant bone is noted. YouTube/ Implantarium/ Rauf Aliyev

 

Three-year follow-up showing healthy gingiva with implant crowns and periapical radiograph demonstrating stable interproximal bone levels

Three-year follow-up examination. a) Buccal view of the implant-supported restorations. The gingiva appears healthy, and the inter-implant papilla has migrated coronally compared to the previous 3-month follow-up. b) Periapical radiograph. The interproximal bone is stable. YouTube/ Implantarium/ Rauf Aliyev

The patient did not attend follow-up appointments for several years, and the next x-ray was taken 9 years after the implants were placed.

Dental implant crowns showing mucosal recession and periapical radiograph at nine-year follow-up examination

Nine-year follow-up examination. a) Buccal view of the implant-supported restorations. Note the mucosal recession observed in the inter-implant and proximal areas. b) Periapical radiograph. The interproximal bone still covers the implant-abutment junction but appears to have lost some height in the coronal portion. YouTube/ Implantarium/ Rauf Aliyev

 

Ten year follow-up showing two dental implants with 1mm spacing, clinical photos and radiographic measurements of inter-implant bone and soft tissue

Ten-year follow-up. a) Buccal view of the restorations seated on two closely spaced implants with an inter-implant distance of 1 mm. The inter-implant papilla and proximal papillae have moved to a more coronal position compared to the 9-year follow-up. b) Occlusal view of the marginal gingiva after removal of the prostheses. The soft tissues appear healthy. c) Periapical radiograph. The interproximal bone occupies the entire space between the concave abutments; it is located more apically compared to the 9-year follow-up. d) Dimensions in the inter-implant area. The implant collar served as internal calibration. Note the distance between the implant collars, the total distance between the concave abutments, and the interproximal bone height. e) Inter-implant distance measurement along the CT axial slice. The value of 1.04 mm confirms the inter-implant distance estimate of 1.02 mm seen on the periapical radiograph. YouTube/ Implantarium/ Rauf Aliyev

Surprisingly, in this particular case, the inter-implant bone crest survived and remained stable even 10 years after the implants were placed.

However, here are the research team’s findings:

“There is no data in the literature on the fate of the interproximal crestal bone at an inter-implant distance (IMD) of Bone Level implants of 1 mm, which requires documentation.
Therefore, the recommendation to maintain at least 3 mm between two implants should still be strictly applied to create the best conditions for preserving inter-implant crestal bone and supporting the interproximal papilla.

However, surprisingly, two papers addressing this issue report that an IMD of 1 mm (which is significantly less than the recommended IMD of 3 mm) does not necessarily result in inter-implant crestal bone loss.

Regarding the described case, the authors suggest that the maintenance of a bone crest height of 1.4 mm coronal to the implant platform for 10 years was probably possible due to the initial subcrestal placement of the implant collars, the presence of a platform switching design, a rough surface extending to the top of the platform, and the increased soft tissue space provided by the concave prosthetic abutments.”

Yes, breaching the safety zone doesn’t always lead to inter-implant bone destruction, and there are successful outliers. But every time a doctor decides on the spacing between implants, they must remember that only a tiny fraction of cases have been successfully documented where the distance between two implants was extremely small. The average patient is unlikely to be so lucky.
Therefore, the 3 mm rule remains highly relevant, and now our readers have a much better understanding of the biology behind why this is so.
That’s all for now. Stay tuned for our next publication.

Disclaimer: Any medical or scientific information provided in connection with the content presented here makes no claim to completeness and the topicality, accuracy and balance of such information provided is not guaranteed. The information provided by Uniqa Dental Ltd. does not constitute medical advice or recommendation and is in no way a substitute for professional advice from a physician, dentist or other healthcare professional and must not be used as a basis for diagnosis or for selecting, starting, changing or stopping medical treatment. Physicians, dentists and other healthcare professionals are solely responsible for the individual medical assessment of each case and for their medical decisions, selection and application of diagnostic methods, medical protocols, treatments and products. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the content and information presented here. Products or treatments shown may not be available in all countries and different information may apply in different countries. For country-specific information please refer to our customer service or a distributor or partner of Uniqa Dental Ltd. in your region.
Curatorial Yurij
Curatorial Yurij
Head of Content at Uniqa Dental As an expert in dental industry, my task is to tell in a simple and fascinating way about complex highly organized series of procedures for the benefit of practitioners.