Osseointegration in the Absence of Primary Stability: What Minipig Overpreparation Model Showed

 

Why this study was conducted

Current publications show contradictory results. Some publications indicate that low primary stability complicates osseointegration and increases the risk of fibrous encapsulation. Others state that the rate of normal osseointegration for implants with critically low primary stability does not differ from that of implants with moderate to high primary stability, provided these implants are not subjected to loading (including healing caps). References supporting both perspectives can be found in the original study text.

Consequently, a research team led by Dr. Thomas Gill designed an experiment to investigate the biological response when an implant is placed into an osteotomy site that has been intentionally or accidentally drilled to a diameter larger than that of the implant.

Additionally, the study examined the influence of surface modification on the rate and quality of osseointegration under these conditions. The implants used for the study were a standard, relatively hydrophobic SLA surface and a modified hydrophilic modSLA surface.

The tests were conducted on minipigs (15 females) aged 12-24 months, with an average weight of 40 kg. These animals were selected because their bone structure and healing processes closely resemble those of humans.

The conditions for implant placement were divided into two groups:

  • Overpreparation – final drill diameter of the osteotomy was larger than the diameter of the implant being placed (final drill 3.5, implant diameter 3.3 mm)
  • Normal Preparation – final drill diameter was 2.8 mm and an implant diameter was 3.3 mm.

Then, after a specified period of time, the results of both groups were compared as accurately as possible based on histological analysis, and the results were interesting.

Research methodology

  • Subjects: Göttingen minipigs, 7 animals for the 2-week stage and 8 for the 8-week stage. Implants were placed in the mandible after the extraction of molars and premolars.
  • Groups:
    • NP (Normal Preparation) – standard site preparation
    • OP (Overpreparation) – over-drilling to eliminate primary stability
  • Implant surfaces:
    Each animal received SLA implants on one side of the jaw and modSLA implants on the other.

    • SLA (standard surface)
    • modSLA (hydrophilic modification)
  • Evaluation time:
    • 2 weeks
    • 8 weeks
  • Evaluation parameters:
    • tBIC — total bone-to-implant contact
    • cBIC — coronal BIC
    • aBIC — apical BIC
    • fBIC — first BIC
    • PCIS — Bone Crest level
    • BATA — bone area to total area
Histological cross-section showing dental implant with marked regions of interest for bone-to-implant contact measurement

Landmarks defined for histomorphometric analysis. The orange line represents the total length for which tBIC is calculated between the first bone to implant contact and last bone to implant contact. For the Coronal ROI, cBIC is measured between the implant shoulder and 2 mm apically (white line). For the apical ROI, aBIC is measured from the white line (2 mm apical to the implant shoulder) to the last BIC (green line).   Wiley Online Library/ Thomas Gill/ 10.1111/clr.70006/ 23 July 2025

Landmarks defined for histomorphometric analysis. The orange line represents the total length for which tBIC is calculated between the first bone to implant contact and last bone to implant contact. For the Coronal ROI, cBIC is measured between the implant shoulder and 2 mm apically (white line). For the apical ROI, aBIC is measured from the white line (2 mm apical to the implant shoulder) to the last BIC (green line). Wiley Online Library/ Thomas Gill/ 10.1111/clr.70006/ 23 July 2025

How the study was conducted

A total of 15 animals were used. Each animal received four implants with different surface types and preparation protocols (see illustration below), resulting in 60 implants available for study. This sample size is sufficient for statistically significant data collection.
Please note that all implants survived and integrated. There were no integration failures or fibrous capsule formations.

Study timeline showing dental implant placement protocol with standard and overpreparation methods across 15 animals over 8 weeks

Overall study design. Overview of surgical timeline, implantation scheme and preparation types. Each hemi-mandible received the same test implant (modSLA or SLA) with one preparation type (Group 1—Normal Preparation or Group 2—Overpreparation).

Implants were placed 20 weeks post-extraction. The alveolar ridge was exposed via a mucoperiosteal flap and leveled using a cylindrical bur under saline irrigation. Implant positions for the two preparation techniques were alternated between the anterior osteotomies (P2/P3 positions).

Resonance Frequency Analysis (RFA) was used to measure primary stability. ISQ was as follows:

  • Group 1 (Normal Preparation): ISQ 69.35 (Sufficient even for immediate loading).
  • Group 2 (Overpreparation): ISQ 11.95 (No primary stability). Furthermore, in Group 2, implants had to be held with tweezers to detach the insertion tool; otherwise, the implant would dislodge with the instrument.

Next, after two weeks, seven animals were selected and samples were obtained for histological analysis. The remaining samples were obtained after eight weeks. The results are summarized in the tables below.

Summary tables of results (Mean values)

Table 1 SLA — Histomorphometry (Mean)

Indicator SLA NP 2w SLA OP 2w SLA NP 8w SLA OP 8w Comment
fBIC (mm) 0.60 0.26 0.69 0.23 OP → First bone contact is closer to the implant shoulder.
CoronalBIC (%) 31.66 56.76 35.19 81.97 OP results in more bone in the coronal area.
ApicalBIC (%) 78.07 70.50 79.40 79.68 Minimal difference by 8 weeks.
TotalBIC (%) 82.20 70.93 84.63 77.09 NP is higher, but OP values approach NP levels over time.
PCIS (mm) 0.11 0.28 0.46 0.28 OP exhibits less apical displacement of the bone level.
PCIS BATA (%) 9.78 50.16 15.23 26.97 OP forms more bone tissue at the coronal aspect.
BATA (%) 50.53 70.70 34.30 59.17 OP shows noticeably more bone formation.

Table 2 modSLA — Histomorphometry (Mean)

Indicator modSLA NP 2w modSLA OP 2w modSLA NP 8w modSLA OP 8w Comment
fBIC (mm) 0.51 0.54 0.37 0.11 OP 8w shows a lower first contact level.
CoronalBIC (%) 28.88 39.25 50.74 76.76 modSLA OP yields the highest coronal BIC.
ApicalBIC (%) 74.90 54.68 78.57 69.09 Lower in OP at both time points.
TotalBIC (%) 68.70 55.97 74.09 66.55 NP is consistently higher.
PCIS (mm) 0.15 0.22 0.25 0.12 OP maintains bone closer to the platform.
PCIS BATA (%) 9.61 26.19 9.79 9.62 NP results in a more uniform distribution.
BATA (%) 32.19 54.43 27.20 48.48 modSLA OP → more bone in the interface area.

Visualization of the dynamics of changes: 2 vs. 8 weeks

Flowchart comparing dental implant success rates between 2-week and 8-week healing periods with sla percentages

What the results show

  1. Even in the absence of primary stability, osseointegration was successful. This is the main and unexpectedly strong conclusion of the study.
  2. Overpreparation does not worsen integration; it may even improve CoronalBIC. This is particularly noticeable in:
  • SLA OP (8 weeks) → coronalBIC 81.97%
  • modSLA OP (8 weeks) → coronalBIC 76.76%That is, in the absence of compression, more bone forms in the coronal aspect, which may have implications for long-term marginal bone stability.
  1. NP shows a higher Total BIC, but the gap narrows. After 8 weeks, the Total BIC values for NP and OP become comparable.
  2. modSLA does not outperform SLA in the absence of primary stability. Under normal conditions, modSLA typically shows accelerated integration, but with OP, modification does not provide any advantages.
  3. OP has lower PCIS (which is unexpectedly good). The crestal bone is preserved closer to the implant platform in the OP groups.

Noteworthy practical implications for clinicians

Neither the authors of the article nor the original study provide clinical recommendations, but they do highlight several important trends that may be useful in real-world practice:

  1. The bone responds more favorably and stably to low compression. OP creates minimal pressure on the cortical plate → less necrosis → higher CoronalBIC.
  2. Even in the absence of primary stability, the implant can integrate. Important: in vivo model does not replace clinical protocols, but shows how the bone reacts to low pressure.
  3. Hydrophilic surfaces provide no benefit if stability is not present. That is, modSLA “loves” stability and fixation.
  4. SLA shows the most predictable results, both with NP and with OP.

Limitations of the study

  • The minipig model does not fully reproduce clinical loading conditions.
  • The lack of masticatory load in the early stages may have improved the results.
  • The short timeframe (2 and 8 weeks) does not reflect long-term implant survival.
  • The comparison was limited to two surface types without including other technologies.

Conclusions

The study demonstrates an important biological fact: Bone is capable of integrating an implant even without primary stability, and excessive site preparation may result in superior preservation of coronal bone.

However, these results should not be directly translated into immediate changes in clinical protocols. Instead, they expand our understanding of how bone responds to pressure, compression, and implant surface variations.

Sources

Osseointegration in the Absence of Primary Stability: An Experimental Preclinical Mandibular Minipig Overpreparation In Vivo Model – Wiley Online Library – 10.1111/clr.70006 – 23 July 2025

Disclaimer: Any medical or scientific information provided in connection with the content presented here makes no claim to completeness and the topicality, accuracy and balance of such information provided is not guaranteed. The information provided by Uniqa Dental Ltd. does not constitute medical advice or recommendation and is in no way a substitute for professional advice from a physician, dentist or other healthcare professional and must not be used as a basis for diagnosis or for selecting, starting, changing or stopping medical treatment. Physicians, dentists and other healthcare professionals are solely responsible for the individual medical assessment of each case and for their medical decisions, selection and application of diagnostic methods, medical protocols, treatments and products. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the content and information presented here. Products or treatments shown may not be available in all countries and different information may apply in different countries. For country-specific information please refer to our customer service or a distributor or partner of Uniqa Dental Ltd. in your region.
Curatorial Yurij
Curatorial Yurij
Head of Content at Uniqa Dental As an expert in dental industry, my task is to tell in a simple and fascinating way about complex highly organized series of procedures for the benefit of practitioners.