Residual cement after the cementation of implant crowns is common and is a recognized cause of peri-implant inflammation. A recent randomized study demonstrated that cement residue was found in almost all cases and that composite (resin) cements leave significantly larger residue areas than glass ionomer cements. Based on these data, this brief review has been prepared to interpret the results, provide practical considerations regarding removal techniques and material selection, and briefly discuss screw retention as an alternative.

Abstract of the original research

A randomized clinical trial (40 patients, 4 groups) compared residual cement after the cementation of monolithic zirconia crowns using glass ionomer (Ketac Cem) and composite (RelyX Unicem) cements at two exposure times (immediate removal and 4 weeks). The main finding: residual cement was detected in 97.5% of cases; composite cement left significantly larger areas of residue.

Why is the problem so important for practitioners?

Residual cement has long been considered a significant and preventable risk factor for peri-implant inflammation. Clinical observations and studies link residual cement fragments to the development of mucositis and, in some cases, peri-implantitis, making this issue relevant for restoration planning and the choice of cementation method. In practice, cement-retained restorations remain popular due to their aesthetics and passive fit, but they require strict excess removal techniques and a careful selection of materials.

In the presented study, the authors note: “Residual cement was detected on 39/40 abutments (97.5%), affecting 137/160 surfaces (85.6%).” They also emphasized: “Resin cement left significantly more residues than glass ionomer (p < 0.001).” These data indicate not only a high frequency of remnants but also that the choice of cement influences the surface area of the remaining material. The following text provides a concise interpretation of the results, practical notes on removal techniques and cement selection, and a brief discussion of screw retention as an alternative for minimizing cement-associated risks.

Study design and methods

The randomized clinical trial included 40 patients, distributed into four equal groups (n=10):

  • GC0 (glass ionomer, immediate removal)
  • GC4 (glass ionomer, removal after 4 weeks)
  • RC0 (resin composite, immediate)
  • RC4 (resin composite, 4 weeks)

All patients received single monolithic zirconia crowns on custom CAD/CAM yttria-stabilized zirconia abutments bonded to Straumann Variobase. Implantation was performed according to a standard protocol with a three-month healing period. Randomization was performed using opaque, sealed envelopes; ethical approval and trial registration complied with CONSORT guidelines and the DRKS registry.

Cad model showing an individual zirconia abutment positioned between adjacent teeth.

CAD construction of the individual zirconia abutment (a).

Cad model showing the implant-supported crown over the customized abutment.

CAD construction of the implant-supported crown (b).

The crowns had occlusal screw access holes for subsequent removal; cementation was performed using Ketac Cem Aplicap (glass ionomer) or RelyX Unicem Aplicap (resin composite). After placement, an experienced clinician removed visible excess cement under 3.6× magnification (dental loupes) using explorers, carbon fiber curettes, and superfloss; cleaning was repeated if necessary until no remnants were visible on the radiograph. The crown-abutment complexes were removed either immediately or after 4 weeks; each unit was photographed from four aspects on a standardized stand.

Four standardized views of the zirconia abutment–crown complex mounted for residual cement assessment.

Standardized photographic documentation of the abutment–crown complex from four aspects (a–d).

Gimp analysis screens marking residual cement on a crown–abutment margin and around peri-implant tissue.

Digital image analysis of residual cement on the crown–abutment complex (a) and in the peri-implant sulcus (b).

Quantitative analysis was performed in GIMP: aspect boundaries were delineated, pixels of the total surface and the area covered by cement were counted, and the ratio of “area with residue/total area” was calculated. Normality of data distribution was not confirmed; nonparametric tests (Kruskal–Wallis followed by Dunn–Bonferroni) were used, with a significance level of p≤0.05. The researchers noted: “Residual cement was detected on 39/40 abutments (97.5%), affecting 137/160 surfaces (85.6%).”

Results obtained

A group of researchers led by Maria Weinreuter obtained a number of clinically significant observations that help to assess the real risk of residual cement in single crowns on implants, as well as the influence of the type of cement and exposure time.

Key data (summary table)

Group Cement Time of removal N Median (Q1–Q3)
GC0 Glass ionomer (Ketac) Immediately 10 0.020 (0.015–0.033)
GC4 Glass ionomer 4 weeks 10 0.042 (0.014–0.087)
RC0 Resin composite (RelyX) Immediately 10 0.078 (0.054–0.114)
RC4 Resin composite 4 weeks 10 0.130 (0.074–0.195)

Key observations and interpretation

  • Frequency: Residual cement was detected in the vast majority of cases; visual and digital analysis showed it was present on most surfaces examined.
  • Type of cement: Composite (resin) cement left significantly larger residue areas compared to glass ionomer; this difference was statistically significant.
  • Exposure time: After 4 weeks, a tendency towards an increase in the area of residual cement was observed, especially in the RC4 group; complete “self-cleaning” due to saliva/hygiene was not confirmed.
  • Localization: Most of the residues were located on the crown/abutment rather than deep in the sulcus; no statistical differences were found between the surfaces (mesial/distal/buccal/lingual).
  • Jaw region: Molars showed higher median residual areas compared to premolars.
  • Radiographic diagnostics: Standard radiographs showed low sensitivity for small or interproximal residues.

These results indicate that even with standardized cementation and thorough cleaning, residue remains common, and the choice of cement significantly influences the amount of material remaining.

Although the composite cement left significantly larger areas of residue, no direct statistically significant relationship was demonstrated between the area/type of residual cement and the severity of inflammatory changes in this study. The modified gingival index increased by one score in only 3 of 40 cases. It should be noted that the study was not designed to detect differences in clinical inflammatory outcomes, and the follow-up period was short-term; larger, longer-term studies are needed to assess the true impact of cement type on the risk of mucositis and peri-implantitis. Such studies do exist; here is a link to one of the most well-known of them.

Practical implications of the data:

  • Risk assessment and material selection. In cases of limited visibility or difficult access (deep margins, interdental spaces, molar areas), glass ionomer materials are preferred—they can reduce the surface area of the remaining material if their retention is clinically sufficient. Composite cements offer better retention but require more thorough and targeted cleaning.
  • Removal technique. The use of magnification (dental loupes), specialized curettes, superfloss, and sequential inspection of all surfaces remains key; radiographs are not reliable for detecting small or buccolingual residues.
  • Time factor. The observed trend toward increased residual area after 4 weeks indicates that oral self-cleaning does not compensate for the shortcomings of the initial cleaning. Planning for monitoring and early revision is warranted if there is any doubt.
  • Alternatives. Screw retention eliminates the problem of cement residue and remains a valid alternative in situations with a high risk of biological complications; its aesthetic and technical limitations should be weighed individually.

Screw retention as a safe alternative

Screw retention eliminates the problem of residual cement by definition and can therefore be an alternative solution, especially for patients with a history of periodontitis, which significantly increases the risk of developing peri-implantitis.

Advantages of screw retention

  • Lack of cement — the source of biological irritation is eliminated.
  • Retrievability for maintenance — easy removal/repair without the risk of leaving residues.
  • Predictability — control of occlusion and retention is easier during repeated interventions, especially with multiple restorations on multi-unit abutments.

Exploded illustration of a dental implant, angled abutment, prosthetic component, and fixation screw.

Limitations

  • Aesthetics — the need to seal the screw access hole may require additional restorative solutions in the anterior zone.
  • Technical nuances — angulation of the access hole, risk of screw loosening, and the need for a passive fit of the restoration.
  • Patient-oriented factors — expectations regarding aesthetics and cost influence the choice.

Practical conclusion: Screw retention is appropriate where the priority is minimizing biological risks and ensuring ease of maintenance; the choice remains with the clinician, taking into account the patient’s anatomy, aesthetics, and preferences.

Limitations of the original study

Small sample size — 40 patients; statistical power to detect differences in clinical outcomes is limited.

Short observation period — up to 4 weeks; long-term biological effects have not been assessed.

Inflammatory outcomes were not the primary endpoint — the study was not designed to reliably estimate the incidence of peri-implantitis.

Measurement method — Photo/pixel analysis provides the area but not the volume of residues; this limits the interpretation of biological impact.

Limited external validity — one standardized removal technique and one experienced operator were used; in daily practice, variability is higher.

Radiographic sensitivity is low — therefore, some of the remnants may have remained undetected radiographically.

Conclusion and findings

The described randomized study confirms that residual cement is a common and clinically significant problem, and the choice of material affects the amount of remnants. Based on the results and clinical interpretation, practical conclusions are drawn:

  • Key takeaway. Cement residue is found in almost all cases even with a standardized technique; composite (resin) cements on average leave larger areas of residue compared to glass ionomer cements.
  • Material. In cases of limited access or high risk of biological complications, preference should be given to cements with a lower tendency to leave extensive residues (e.g., glass ionomer), if their retention is clinically sufficient.
  • Technique. Magnification (loupes/microscope), systematic cleaning of all surfaces, the use of fine instruments and superfloss, and visual inspection with repeated revision until complete certainty of the absence of visible residues are required.
  • Observation plan. When in doubt, early monitoring (within the first few weeks) and a low threshold for revision are recommended; self-cleaning of the oral cavity does not compensate for the shortcomings of primary cleaning.
  • Alternative. Screw retention eliminates the problem of cement and is advisable in cases of high risk of peri-implant complications or limited access for cleaning.
  • Patient risk assessment. A history of periodontitis, smoking, uncontrolled diabetes, and poor hygiene increase the risk; the choice of the retention method and material should take these factors into account.
  • Scientific context. Larger, longer-term studies that focus on the association of remnant amounts with long-term biological outcomes are needed for definitive clinical recommendations.

Rule of thumb: If there are any doubts about accessibility for thorough cleaning, either choose a technique/material with a lower risk of residue, or prefer screw retention.

Source

Residual Cement Excess of Composite Versus Glass Ionomer Cement in Implant-Supported Single Crowns After Different Intraoral Exposure Times—A Randomized Controlled Clinical Trial – CLINICAL ORAL IMPLANTS RESEARCH – First published: 08 March 2026

Disclaimer: Any medical or scientific information provided in connection with the content presented here makes no claim to completeness and the topicality, accuracy and balance of such information provided is not guaranteed. The information provided by Uniqa Dental Ltd. does not constitute medical advice or recommendation and is in no way a substitute for professional advice from a physician, dentist or other healthcare professional and must not be used as a basis for diagnosis or for selecting, starting, changing or stopping medical treatment. Physicians, dentists and other healthcare professionals are solely responsible for the individual medical assessment of each case and for their medical decisions, selection and application of diagnostic methods, medical protocols, treatments and products. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the content and information presented here. Products or treatments shown may not be available in all countries and different information may apply in different countries. For country-specific information please refer to our customer service or a distributor or partner of Uniqa Dental Ltd. in your region.
Curatorial Yurij
Curatorial Yurij
Head of Content at Uniqa Dental As an expert in dental industry, my task is to tell in a simple and fascinating way about complex highly organized series of procedures for the benefit of practitioners.