Impact of Marginal Misfit in Implant-Supported Fixed Dental Prostheses on Peri-Implant Bone Levels: A Retrospective Quantitative Analysis
Contents
Long-term stability of marginal bone around dental implants is the “gold standard” for success in modern implant dentistry. Traditionally, the primary focus has been on the surgical protocol, implant surface quality, and patient hygiene. However, a recent large-scale study by Couso-Queiruga et al. (2025), published in the journal Clinical Oral Implants Research, significantly changes our understanding of the role of the prosthetic phase.
A study titled “Impact of prosthetic misfit on marginal bone levels: A 10-year retrospective quantitative analysis” provides compelling evidence that even microscopic imperfections in the fit of crowns can determine the fate of bone tissue for decades to come.
At first glance, these are micron-sized gaps that are difficult to detect even on a radiograph. In clinical practice, one often hears, “What do these hundredths of a millimeter matter? The main thing is that the implant osseointegrates.” However, these very microgaps can become the source of problems that won’t manifest immediately, but years later.
Why is this important?
- Mechanics: The misfit creates additional stress at the implant-bone-prosthesis interface.
- Biology: The microgap becomes a reservoir for biofilm, where bacteria find ideal conditions for proliferation.
- Immunology: Metabolic products of microorganisms stimulate inflammation, activate osteoclasts, and initiate the process of bone resorption.
Until recently, the evidence base on this issue was limited. While individual studies have pointed to a link between prosthetic misfit and complications, there has been no systematic, long-term analysis.
This is precisely why the work of Emilio Couso-Queiruga and colleagues from the University of Bern (2025) is considered a landmark study. The authors set an ambitious goal:
- To evaluate the influence of marginal misfit in implant-supported prostheses on the peri-implant bone level.
- To determine the threshold value of misfit at which the risk becomes clinically significant.
- To identify additional risk factors that may exacerbate or mitigate the impact of misfit.
A key feature of the study is its long-term follow-up. The authors returned to patients who received implants in the late 1990s and early 2000s and assessed their condition ten years after the initial loading. This retrospective analysis allows us to understand the true state of affairs.
Materials and methods
When we say “retrospective study,” many colleagues associate it with a dry analysis of archival data. But in this case, we are talking about a carefully designed study, where every detail was thoroughly considered. The authors took patients who had received implants in the late 1990s and early 2000s and followed up with them ten years after loading. This design allowed them to observe not only early complications but also how bone tissue behaves over the long term.
Design and ethics
The study was conducted at the University of Bern across three departments: periodontology, oral surgery, and reconstructive dentistry. The protocol complied with the Declaration of Helsinki and was approved by the Ethics Committee of the Canton of Bern. It is important to emphasize that even retrospective studies require strict adherence to ethical standards, especially when reusing clinical data.
Sample
The analysis included 301 patients and 505 implants. The average age was approximately 50 years, but the range was wide, from young adults to the elderly. The gender distribution was nearly equal: 47% men and 53% women.
Particular attention was paid to risk factors:
- 12% of patients were smokers, with an average smoking history of about 18 pack-years.
- 35% had a history of periodontitis.
- 5% suffered from diabetes, and 3% from osteoporosis.
- More than two-thirds consumed alcohol.
Thus, the sample reflected a real-world clinical picture, and not just “ideal” patients without comorbidities.
Clinical procedures
The implants were placed according to the protocol of the late 1990s: tissue-level placement, with slight subcrestal positioning. In some cases, bone augmentation or sinus floor elevation was performed. Importantly, most implants functioned without additional interventions, allowing for an assessment of the “pure” fit of the prosthesis.
Data collection
Ten years after loading, standard periapical radiographs were taken. The distance from the implant shoulder to the first bone-to-implant contact (DIB) was measured. To eliminate subjectivity, two independent experts used ImageJ software. In case of discrepancies greater than 0.3 mm, recalibration was performed and a consensus was reached.
In addition, the presence or absence of a marginal gap (GapCAT) and its size (GapDIM) were recorded. The classification was three-tiered:
- 0 mm,
- 0–<0.1 mm,
- ≥0.1 mm.
This made it possible not only to divide patients into “with a gap” and “without a gap,” but also to evaluate the dose-dependent effect.

A clinical case illustrating a radiographic misfit of the implant-supported prosthesis and peri-implant marginal mucosal dehiscence, exposing the implant surface.
Statistical analysis
A linear mixed model was used to process the data. This approach takes into account repeated measurements within a single patient and allows for the identification of true patterns while eliminating random fluctuations.
- T-tests and ANOVA were used to compare groups.
- For non-normally distributed data, non-parametric tests (Mann-Whitney, Kruskal-Wallis) were used.
- Statistical significance was set at p < 0.05.
Thus, the methodology was designed to minimize the risk of errors and obtain reliable conclusions.
Results
When we talk about the results of a ten-year follow-up, it is important to remember that these are not just statistics, but a reflection of real clinical practice.
The big picture
The average DIB (the distance from the implant shoulder to the coronal bone level) was 3.3 ± 0.7 mm. At first glance, this figure seems quite acceptable, but the devil, as always, is in the details.

Graphical analysis of gap distribution in relation to the number and locations of dental implants.
Influence of edge gap
The authors divided the implants into groups based on the presence and size of marginal misfit.
- Without a gap: DIB = 3.22 ± 0.8 mm.
- With a gap: DIB = 3.43 ± 0.6 mm.
- The difference is statistically significant (p = 0.0018).
If we delve deeper:
- Gap ≥0.1 mm: DIB = 3.45 ± 0.7 mm.
- Gap >0–<0.1 mm: DIB = 3.36 ± 0.5 mm.
- No gap: DIB = 3.22 ± 0.7 mm.
Every additional 0.1 mm of gap resulted in a 0.08 mm increase in DIB (p = 0.03). This may seem like a small amount, but over a ten-year period, this represents a significant loss of bone tissue.
Table 2. Radiographic parameters
ParameterValue
Average DIB 3.3 ± 0.7 mm
ISP without a gap 3.22 ± 0.8 mm
ISP with a gap 3.43 ± 0.6 mm
Gap ≥0.1 mm 3.45 ± 0.7 mm
Gap >0–<0.1 mm 3.36 ± 0.5 mm
DIB increase for every 0.1 mm gap +0.08 mm
Additional risk factors
The study showed that it is not misfit alone that affects bone levels.
- Smoking: increased DIB by 0.36 mm.
- History of periodontitis: +0.16 mm.
- Diabetes: no statistically significant effect was found.
- Transcrestal sinus floor elevation: unexpectedly showed a protective effect—a decrease in DIB by 0.54 mm.
Clinical observations
Interestingly, the presence of residual cement was rarely recorded—in only 11 cases. This indicates that the primary factor in this study was indeed related to the accuracy of fit, rather than other prosthetic complications.
Discussion
When we look at the raw numbers—3.22 mm versus 3.43 mm—the difference seems small. But from a clinical perspective, this isn’t just statistics. It represents tens of microns of bone tissue lost annually. And when you add risk factors like smoking and periodontitis, the picture becomes even more alarming.
Mechanisms underlying the impact of misfit
The study’s authors highlight several possible mechanisms:
- Mechanical stress: Misfit creates stress at the implant-bone-prosthesis interface. Even minimal gaps can lead to micromovements, which in the long term stimulate resorption.
- Biofilm: The microgap becomes a reservoir for bacteria. In conditions where access for hygiene is limited, this is an ideal niche for microorganisms.
- Inflammation: Bacterial products stimulate osteoclasts, trigger a cascade of inflammatory reactions, and gradually lead to bone loss.
The role of additional factors
Interestingly, smoking and periodontitis exacerbate the negative effects of misfit. This makes sense: both factors are associated with impaired microcirculation and a weakened immune response. As a result, even a small gap becomes more dangerous.
The protective effect of transcrestal sinus floor elevation was unexpected. The authors suggest that this is due to the specifics of the surgical technique: perhaps additional stimulation of bone tissue and its remodeling create a more stable environment around the implant.
Clinical perspective
For a practicing dentist, the main conclusion is simple: precision fit is no minor detail. Even the slightest misfit can change the fate of an implant over a ten-year horizon.
In a conversation with colleagues, this can be formulated as follows:
“We often think that the most important thing is to place the implant correctly. But the prosthetic component is no less important. If there’s a gap, even just 0.1 mm, we’ll see a difference in bone level within ten years.”
Limitations of the study
The authors frankly note that the study is retrospective, which imposes limitations. Not all factors could be accounted for, and not all data were perfectly standardized. However, the study’s strength lies in its long-term follow-up and the large number of patients.
Practical significance
n clinical practice, we often see a focus on the surgical stage: implant selection, placement technique, and bone quality. The prosthetic stage is perceived as “technical work,” where aesthetics and functionality are paramount. However, research from the University of Bern shows that prosthetic precision can be a key factor in long-term stability.
What does this mean for the practicing dentist?
- Gaps ≥0.1 mm — this is not just a number in a table, but a real risk to bone tissue.
- Smoking and periodontitis exacerbate the negative effect of misfit, turning the microgap into a trigger for resorption.
- Transcrestal sinus floor elevation unexpectedly showed a protective effect, which opens up an interesting avenue for further research.
It’s important to emphasize: we don’t make direct recommendations. However, the study’s findings should encourage careful consideration. A precise fit is not a luxury, but a necessity.
In an informal conversation with colleagues, this can be formulated as follows:
“We’re used to thinking of implant dentistry as a surgical procedure. But the prosthetic part is no less important. If there’s a gap, even just 0.1 mm, we’ll see a difference in bone density within ten years.”
Conclusion
The study by Emilio Couso-Queiruga and colleagues marked an important step in understanding how prosthetic misfit affects implant stability. Over a ten-year horizon, even minimal gaps prove significant.
Key findings:
- Marginal misfit is associated with increased DIB and, consequently, bone loss.
- The threshold value is ≥0.1 mm, which is clinically significant.
- Smoking and periodontitis exacerbate the negative effect.
- Transcrestal sinus floor elevation may have a protective effect.
For a practicing dentist, this is a signal: precision is not a minor detail, but a factor that can change the fate of an implant.
📖 Source:
Couso‐Queiruga E., Ramseier C. A., Chappuis V., Janner S. F. M., Brägger U., Salvi G. E., Buser D. Impact of Marginal Misfit in Implant‑Supported Fixed Dental Prostheses on Peri‑Implant Bone Levels: A Retrospective Quantitative Analysis. Clinical Oral Implants Research, 2025. DOI: 10.1111/clr.70053
-
Hot
-