3D Printing in Bone Grafting: How Osseointegration Occurs in Mandibular Augmentation with 3D-Printed Hydroxyapatite Blocks
Contents
Almost every dental surgeon faces the need to treat bone defects. Guided bone regeneration, using a mixture of autogenous particulate bone and synthetic or animal-derived bone substitutes, is excellent for filling extraction sockets and contained bone defects. However, when it comes to increasing the height of the alveolar crest, particulate bone graft materials are not suitable.
Furthermore, standard bone blocks (e.g., xenogeneic DBBM) have a number of critical drawbacks: they are brittle, often fracture during screw fixation, and have an unpredictable internal structure, which hinders vascular ingrowth.
A study by Systermans et al. (2026), published in Clinical Oral Implants Research, offers a fundamentally different approach: the use of 3D-printed blocks of pure hydroxyapatite (3DHA) with a mathematically defined gyroid architecture.
1. Introduction: Overcoming the Limitations of Bone Blocks
The main problem with traditional blocks is their heterogeneity. We cannot control the exact arrangement of pores within a piece of animal bone. Often, the pores are too small and randomly distributed. 3D printing solves this problem. The researchers used “gyroid” geometry—a complex curvilinear structure that:
- Provides interconnected porosity for unimpeded angiogenesis.
- Exhibits high mechanical strength and low weight.
- Allows the block to withstand compression and torque during implant placement.
The main goal of the study was to investigate whether it is possible not only to augment bone volume with this material but also to place an implant within it, achieving complete osseointegration comparable to native bone.
2. Study Design: How the Technology Was Tested
To ensure the validity of the experiment, a large animal model (Göttingen minipigs) was chosen, as their bone regeneration closely resembles that of humans.
The process was divided into three stages:
- T0 (Augmentation): Lateral mandibular augmentation. 3DHA blocks were fixed with two osteosynthesis screws and covered with a collagen membrane.
- T1 (Implantation): After 8 or 12 weeks (depending on the group), dental implants were placed. Importantly, the implant site was prepared directly through the block, incorporating both the 3DHA material and the host’s native bone.
- T2 (Final): After another 12 weeks, histomorphometric analysis was performed to assess bone-to-implant contact (BIC).

Schematic representation of the animal model including the 3DHA size, bone augmentation location, fixation, and healing periods.
This design allowed researchers to evaluate not only biological success (graft incorporation) but also clinical applicability—how convenient it is for a clinician to work with this material in a surgical setting.
3. Surgical Ergonomics: A Clinician-Controlled Bone Block
One of the surgeon’s main concerns when working with blocks is the risk of material fracture when tightening a screw or preparing the implant site. In the study by Systermans et al., 3DHA blocks with a gyroid structure proved to be an exceptionally stable material.
Key observations:
- Fracture-free fixation: The blocks were easily secured with standard osteosynthesis screws. No cases of splitting or damage to the block structure were observed during screw tightening [1].
- Precision drilling: The implant site was prepared using a standard protocol. Unlike xenogeneic blocks, which can crumble, 3DHA maintained the integrity of the osteotomy margins. This allowed for highly accurate implant positioning [1].

Intra-operative pictures at T0 (A, B) and T1 (C, D). (A) 3DHA fixed with 2 screws. (B) Collagen membrane covering the graft. (C) Osseointegrated 3DHA after the first healing period. New bone is visible macroscopically on the 3DHA surface. (D) Dental implant placed inside the 3DHA.
4. Augmentation Results: Bone Where There Was None
Numbers are the best argument for a clinician. The study demonstrated impressive results in alveolar ridge volume restoration.

Schematic representations of the regions of interest of the histomorphometric analysis. Transversal section of the scaffold area crossing the dental implant and both screws.
Linear Bone Gain:
The average increase in jaw width was 4.73 mm[1] This volume is more than sufficient for the placement of a standard-diameter implant in the posterior regions.
Histomorphometric Analysis (Quality of “New” Bone):
The researchers assessed how actively the block was being replaced by living tissue. Mature, well-vascularized bone was found within the pores of the block.
Table 1. Composition of the augmented site 12 weeks after block placement (summary data).
| Component | Percentage (%) | Clinical significance |
|---|---|---|
| New bone formation (NB) | 39.17% | Active regeneration and biointegration [1] |
| Residual material (3DHA) | 28.60% | The block serves as a reliable scaffold without resorbing too quickly [1] |
| Soft tissues / Vessels | 32.23% | A high level of vascularization ensures the viability of the site [1] |

Histological sections. (A) Biopsy sagittal section at T1 (McNeal staining; specimen 4R). (B) Native bone and scaffold area interface (polarized light). (C) Bone remodelling highlighted by cement lines (black arrows) and numerous osteoblasts (McNeal staining). (D) Bloods vessels inside the new bone (blue arrows) (HE staining). (E) Transversal section of the scaffold area highlighting the vertical bone gain, the dental implant placement, and the screws. Interface between dental implant and new bone are enlarged (McNeal staining; specimen 2R). (F) Transversal section of the scaffold area of the dental implant with enlarged view of dental implant—new bone interface (McNeal staining; specimen 3R). (G) Enlarged view of dental implant—new bone interface (HE staining; specimen 3R). Yellow arrows indicate osteoblasts and bone growth towards the dental implant. Legend: ‘X’: 3DHA; ‘#’: New bone (woven bone); ‘ = ’: Native cortical bone; ‘Y’: Dental implant; ‘Z’: Osteosynthesis screws.
Important conclusion: 3D-printed hydroxyapatite does not simply occupy volume; it acts as a “biological scaffold” for the host’s own bone growth. Furthermore, the 8-week and 12-week healing periods showed comparable results, suggesting the possibility of reducing the waiting time before the second stage [1].
5. Osseointegration of the Implant: Block vs. Native Bone
For the practitioner, it is critical that the implant is stable not only in the native bone but also in the augmented site. The study confirmed that the gyroid structure of 3DHA provides excellent mechanical support.
Primary Stability:
In all cases, an insertion torque of 35 Ncm was achieved during implant placement. This is the gold standard, ensuring successful integration and, in certain clinical cases, allowing for immediate provisionalization and soft tissue conditioning.
Bone-to-Implant Contact (BIC):
Histological analysis revealed striking results. The percentage of implant surface contact with living bone within the 3D-printed block was even higher than in the animal’s native bone.
Table 2. Bone-to-Implant Contact (BIC) values 12 weeks after implantation
| Contact zone | Average BIC (%) | Clinical conclusion |
|---|---|---|
| Inside the block (augmented site) | 42.79% | Reliable integration within an artificial scaffold |
| In native bone | 34.17% | Standard level of osseointegration |
| Total BIC | 38.48% | High overall primary stability |
Why is the BIC higher in the block?
Scientists attribute this to the geometry of the gyroid structure: the pores of the block hold the regenerating bone in close proximity to the surface of the implant, creating a kind of “protected chamber” for osteoblasts.
6. Clinical Significance for the Practicing Dentist
The study by Systermans et al. (2026) moves 3D printing of bone blocks from the realm of futurology to the realm of predictable surgery.
Key practical conclusions:
- Reduced treatment times: There is virtually no difference between the 8- and 12-week healing periods before implant placement. This allows the clinician to begin the second surgical stage earlier.
- Elimination of brittleness: Unlike xenogeneic blocks, 3DHA allows the clinician to prepare the implant site and tighten screws without fear of losing the graft due to splitting.
- Personalization (CAD/CAM): The technology allows for printing blocks precisely tailored to a specific patient’s defect using CBCT data, minimizing surgical time spent on material adjustment.
Result
3D-printed hydroxyapatite blocks with gyroid porosity are a reliable platform for dental implantation. They provide significant bone gain (~4.7 mm) and allow for osseointegration that is in no way inferior—and in some aspects superior—to that in native bone.
For the dentist working with large-volume reconstructions, this means a transition to faster, more precise, and less traumatic surgeries.
Original study: Systermans et al., 2026. Dental Implant Osseointegration Following Mandibular Augmentation Using 3D Printed Hydroxyapatite Blocks.
-
Hot
-