Clinical Significance of Crown and Abutment Height for the Strength of Zirconia Restorations: An In Vitro Study
Contents
Almost every dental practitioner encounters mechanical complications with restorations. These include fractured crowns or loose screws. It’s not uncommon for patients to present holding their broken restorations. This requires disrupting the schedule and wasting time and resources on urgently remaking or repairing the restoration.
This is especially distressing in the esthetic zone—the upper central incisors. Here, any failure is immediately noticeable, and the patient’s demands for strength and esthetics are at their highest.
This is the problem that a team of researchers led by Dr. Esha Zahid from the Melbourne Dental School, University of Melbourne (Australia) addressed. In their work (Clinical Oral Implants Research, 2026; 37:867‑882. doi:10.1111/clr.70130), they studied in detail for the first time how crown height and Ti-base abutment retention height affect the strength and survival of monolithic zirconia crowns under cyclic loading conditions.
For a practicing dentist, this research is not a laboratory abstraction, but rather concrete figures that help them understand which designs will withstand years of use, and which are at risk of premature failure.
Who conducted the research and where did it take place?
The study was carried out at the Melbourne Dental School, University of Melbourne—one of the leading centers of dental science in Australia. The university is known for its work on the biomechanics of implants and the durability of restorations, and its laboratories regularly publish research in Clinical Oral Implants Research and other international journals.
The project lead, Dr. Esha Zahid, specializes in the strength and durability of CAD/CAM restorations. Her previous work examined the fatigue strength of zirconia restorations and the impact of digital technologies on crown fit accuracy.
Co-author Jaafar Abduo is a renowned researcher in the field of prosthodontics and digital technologies, whose publications are often cited in reviews on CAD/CAM systems. Joseph Palamara has extensive experience in materials science and the microstructural analysis of zirconia, including SEM studies of crack formation.
Thus, the team behind this project combines the clinical experience of prosthodontists with in-depth laboratory expertise in materials science. This explains why the study was not simply a “strength test,” but a comprehensive analysis of the factors influencing restoration survival.
Methodology in a nutshell
-
Samples and groups
-
A total of 40 monolithic zirconia crowns for the upper central incisor were fabricated.
-
Straumann BL implants Ø4.1×10 mm and Ti-base abutments Variobase Ø4.5 mm were used.
-
4 groups of 10 samples were formed:
-
SLA — short crown (13 mm), long abutment (5.5 mm).
-
SCSA — short crown (13 mm), short abutment (3.5 mm).
-
LCLA — long crown (16 mm), long abutment (5.5 mm).
-
LCSA — long crown (16 mm), short abutment (3.5 mm).
-
-

Final assembly of right maxillary central incisor monolithic zirconia implant crowns prior to loading. (A, B) 13 mm crown, (C, D) 16 mm crown.
-
Crown material
-
4th generation multilayer zirconia (Upcera Explore Esthetic, Shade A2).
-
Material strength: 727–1000 MPa (from the incisal edge to the cervical margin).
-
CAD/CAM design without modification of abutments, cemented on Ti-bases using Multilink Hybrid Abutment.
-
-
Retention
-
The abutment screws were torqued to 35 Ncm and retorqued after 10 minutes.
-
The screw channels were sealed with composite.
-
-
Aging of samples
-
Thermal cycling: 5000 cycles at 5°C and 55°C (equivalent to ~6 months of clinical use).
-
Mechanical fatigue load: cyclic loading at an angle of 30° to the implant axis, starting at a load of 450 N, followed by a stepwise increase of 50 N every 30,000 cycles until failure.
-
-
Measurements
-
The following were recorded:
-
failure load (N)
-
number of cycles to failure
-
type of failure (crown, abutment, screw, their combinations).
-
-
A Weibull analysis was additionally conducted to assess the probability of failure.
-
Fractography: stereomicroscope + SEM for crack and fracture pattern analysis.
-
-
Statistics
-
The data were tested for normality (Shapiro-Wilk) and equality of variances (Levene).
-
Nonparametric tests (Kruskal-Wallis, Mann-Whitney U with Bonferroni correction) were used to compare groups.
-
Thus, the study combines rigorous laboratory preparation (CAD/CAM, standardized retention, thermal cycling) and comprehensive analysis (load, cycles, Weibull, SEM). This makes the results reliable and clinically relevant.

CAD design of 13 and 16 mm implant crowns with 3.5 and 5.5 mm Ti-base abutments. (A) SCLA, (B) SCSA, (C) LCLA, (D) LCSA.
Key facts and figures
Failure load (N)
| Group | Mean | SD | Minimum | Maximum |
|---|---|---|---|---|
| SCSA (short crown, short abutment) | 536.9 | 78.4 | 449 | 703 |
| SCLA (short crown, long abutment) | 493.4 | 53.2 | 440 | 595 |
| LCLA (long crown, long abutment) | 491.3 | 40.7 | 448 | 552 |
| LCSA (long crown, short abutment) | 453.7 | 2.8 | 449 | 457 |
Conclusion: The highest strength is found in the short crown with a short abutment (SCSA), while the lowest is in the long crown with a short abutment (LCSA).
Number of cycles to failure
| Group | Mean | SD | Minimum | Maximum |
|---|---|---|---|---|
| SCSA | 72,492 | 44,551 | 24,677 | 169,453 |
| SLA | 43,630 | 27,579 | 18,928 | 98,939 |
| LCLA | 37,706 | 18,826 | 19,693 | 69,474 |
| LCSA | 8,399 | 7,308 | 626 | 20,579 |
Conclusion: The short crown with a short abutment withstood almost 9 times more cycles than the long crown with a short abutment.
Types of failure
| Group | Main failures |
|---|---|
| SCSA | 90% – abutment, no damage to the crown |
| SLA | 78% – abutment + screw |
| LCLA | 33% – abutment + crown; 22% – crown; 33% – abutment |
| LCSA | 56% – crown; 33% – abutment; 11% – abutment + crown |
Conclusion: Short crowns more often caused failure in the abutments and screws, whereas long crowns resulted in fracture of the crowns themselves.
Key observations
-
Short crowns showed better survival and durability.
-
With long crowns, the crowns themselves fractured more often than not.
-
Abutment height had less significance, but the combination of “short crown + short abutment” yielded the best results.
-
LCSA was the weakest combination: a long crown and a short abutment.
Dynamics and types of failures
Short crowns (13 mm)
-
SCSA (short abutment)
-
90% of cases were abutment fractures.
-
The crown remained intact; the failure occurred at the level of the Ti-base platform.
-
The screw remained intact.
-
-
SCLA (long abutment)
-
In 78% of cases, abutment + screw fractured simultaneously.
-
The fracture occurred below the Ti-base platform, while the crown remained intact.
-
In one case, a rare condition was recorded: implant fracture (excluded as an anomaly).
-
Long crowns (16 mm)
-
LCLA (long abutment)
-
33% — abutment + crown fractured together.
-
22% — crown fractured separately.
-
33% — abutment fractured separately.
-
11% — isolated screw failures.
-
-
LCSA (short abutment)
-
56% — crown fractured.
-
33% — abutment failures.
-
11% — combined abutment + crown failures.
-
Mechanics of failure
-
Short crowns: The load was concentrated on the abutment and screw. The crown remained intact, but the metal components became the “weak link.”
-
Long crowns: These created a distinct cantilever effect: the load was transferred to the crown itself, and cracks propagated from the base (at the junction with the abutment) up the proximal or buccolingual surfaces.
-
SEM analysis showed that cracks initiated in the area of the crown-abutment junction, where stress was concentrated, and propagated towards the surface.

Light microscope images from the representative specimens from the study groups. (A) SCLA specimen depicting abutment and screw fracture, (B) SCSA specimen depicting abutment fracture, (C) LCLA specimen depicting crown fracture.

Group SCSA specimen: SEM image of an abutment fracture (×20 for A) and (×100 for B). The images above show T (tensile zone), C (compressive zone), and * (compression curl) with the arrow indicating the direction of the curl.

Group SCLA specimen: SEM image of an abutment and screw fracture (×20 for A) and (×100 for B). The images above show T (tensile zone), N (neutral axis), and CZ (compressive zone).

Group LCLA specimen: Light microscopy image of crown fracture (A). Point of crack initiation (Thin arrow) on the internal surface of the crown and Hackle lines projecting outwards (thick arrow). SEM image of a crown fracture (×30 for B and C). The point of initiation of crack (P) can be seen on the internal surface of the crown in B. Hackle lines (H) radiating from the fracture origin. C depicts a conchoidal fracture (CF) showing smooth, curved fracture surface with distinct ripples reminiscent of curved seashells (Quinn 2006).
Key takeaway
-
A short crown breaks the metal components (abutment, screw).
-
A long crown fractures itself.
-
The most vulnerable combination is a long crown + short abutment (LCSA): it demonstrated the lowest strength, minimal number of cycles, and a high percentage of crown fractures.
Interpretation and implications for practice
-
Crown height decides the fate of the restoration. Short crowns (13 mm) demonstrated better strength and survival. Long crowns (16 mm) were more likely to fracture, creating a cantilever effect and overloading the material.
-
The abutment plays a secondary role. The difference between the short (3.5 mm) and long (5.5 mm) abutments was less significant than the crown height. However, the short crown + short abutment combination yielded better results in terms of load and cycles.
-
The type of failure depends on the design.
-
Short crowns broke the metal components – abutments and screws.
-
Long crowns fractured themselves, and cracks spread from the base upwards.
-
-
Clinical significance.
-
If a crown is too long, the clinician must understand that the risk of fracture increases significantly.
-
A short crown is not just about esthetics, but also about mechanical stability.
-
The height of the abutment is important, but not critical: the decisive factor remains the length of the crown.
-
For the practicing dentist
-
Crown height in millimeters is not just a number in a CAD design, but a factor that determines whether the restoration will last for years or fail in a few months.
-
A long crown in the esthetic zone is a compromise that can lead to complications.
-
A short crown provides a better chance of long-term stability, even when the load is high.
Conclusions
-
Crown height is a key factor. Short crowns (13 mm) showed better strength and survival, while long ones (16 mm) exhibited higher rates of crown fracture.
-
The abutment plays a secondary role. The difference between a short and a long abutment is less significant than the crown height. However, the “short crown + short abutment” combination yielded the best overall results.
-
The type of failure depends on the design. Short crowns overload the abutments and screws, while long crowns overload the crowns themselves.
-
Practical significance. If the clinical situation leads to an excessive crown height, it is worth considering modifying the clinical parameters in advance—before cracks and complications appear.
Thus, the research by Dr. Esha Zahid’s team demonstrates: Crown height in millimeters determines the fate of the restoration. For a practicing dentist, this isn’t a laboratory theory, but rather specific figures that help predict the stability and longevity of implants in the esthetic zone.