It’s incredibly frustrating when a patient returns after several years with problems around the implant. Inflammation, recession, mobility—and the entire carefully constructed restoration is at risk. Instead of the promised “decades of reliability,” you have to pick up the instruments again, explain the situation to the patient, and essentially start all over again.

This isn’t just a professional frustration; it’s also a blow to patient trust. One factor that has long remained obscure is the width of the keratinized mucosa around the implant. Millimeters of tissue, seemingly insignificant at first glance, can be decisive in determining whether the peri-implant tissue remains healthy or a chain of problems begins.

This is the topic that was the focus of an international team of researchers led by Dr. Maurício Guimarães Araújo (State University of Maringá, Brazil, in collaboration with Queen Mary University of London and Nova Southeastern University, USA). Their 10-year follow-up is a rarity in modern implantology. In the article by Costa Deller F.A. et al., Clinical Oral Implants Research, 2026; 37:785‑795. doi:10.1111/clr.70123, they showed how the width of the mucosa affects inflammation, recession, plaque accumulation, and even the patient’s comfort during brushing.

Who conducted the research and where did it take place?

Behind this 10-year project is an international team led by Dr. Maurício Guimarães Araújo. The study involved specialists from three reputable centers:

  • State University of Maringá (Brazil) – clinical site and main observation center.

  • Queen Mary University of London (UK) – scientific support and data analysis.

  • Nova Southeastern University, Florida (USA) – expertise in periodontology.

  • Additionally, biostatisticians from São Paulo State University (Brazil).

This collaboration allowed for the combination of clinical experience, international diagnostic standards, and rigorous statistical data processing. The result was a project of rare duration and quality: 10 years of monitoring implants in real patients.

The authors of the article—Fernanda Angelio da Costa Deller, Jeniffer Perussolo, Andre Barbisan de Souza, Ricardo Puziol de Oliveira, Flávia Matarazzo and Maurício G. Araújo—presented the results in the journal Clinical Oral Implants Research (2026).

Methodology in a nutshell

To ensure that the results were valid, the researchers developed a rigorous observation protocol.

  • Patients:

    • At baseline, there were 80 patients with implants.

    • After 10 years, 30 patients remained (21 women, 9 men), with a mean age of 61 years.

    • A total of 116 implants were evaluated, with a loading period of about 15 years.

  • Groups:

    • NG (Narrow Group)—keratinized mucosa width <2 mm.

    • WG (Wide Group)—keratinized mucosa width ≥2 mm.

  • What was measured:

    • Plaque Index (PI, mPI)

    • Probing depth (PD)

    • Clinical attachment level (CAL)

    • Mucosal recession (REC)

    • Bleeding on probing (BoP)

    • Marginal bone level (MBL)

    • Subjective brushing discomfort (BD)

Diagnostics:

  • The international classification was used (Berglundh et al., 2018; Herrera et al., 2023):

    • Health—absence of inflammation and stable bone levels.

    • Mucositis—bleeding, but without bone loss.

    • Peri-implantitis—bleeding/suppuration + increased pocket depth + bone loss.

  • Quality control:

    • All measurements were performed by periodontists working according to a standardized protocol to ensure the reliability of the results.

    • Inter-examiner reliability was verified: the agreement coefficient was >0.85.

    • Radiographic assessment – digital radiographs analyzed using specialized software.

Thus, the study combines clinical practice and rigorous statistics: the data is not random, but verified and comparable.

Key facts and figures

The study showed that the width of the keratinized mucosa directly affects the condition of the tissues around the implant.

Comparison of NG (<2 mm) and WG (≥2 mm) after 10 years

Parameter NG (narrow mucosa) WG (wide mucosa) Difference
Plaque Index (PI) 0.70 ± 0.35 0.41 ± 0.38 Significantly higher in NG
Modified PI (mPI) 0.88 ± 0.57 0.45 ± 0.48 Greater plaque accumulation in NG
Bleeding on probing (BoP) 48% 29% Inflammation is more common in NG
Mucosal recession (REC) 0.52 ± 0.72 mm 0.17 ± 0.44 mm Recession is more pronounced in NG
Marginal bone level (MBL) 2.30 ± 1.21 mm 1.98 ± 1.01 mm Greater bone loss in NG
Diagnosis (T10) Healthy: 21.5%
Mucositis: 72.3%
Peri-implantitis: 6.2%
Healthy: 41.2%
Mucositis: 54.9%
Peri-implantitis: 3.9%
Patients in WG remain healthy twice as often
Odds Ratio (risk of disease) — 0.16 (84% lower risk) WG protects against disease

What does this mean in numbers?

  • In the group with narrow mucosa, plaque and bleeding occurred almost twice as often.

  • Recession in NG was more pronounced (0.52 mm versus 0.17 mm).

  • Tissue health after 10 years was maintained in 41% of implants in WG and only 21% in NG.

  • Risk of disease in WG was 84% lower (OR=0.16).

Thus, even a few millimeters of mucosa around the implant prove to be a critical factor: narrow mucosa leads to chronic mucositis and recession, while wide mucosa acts as a natural “shield.”

Baseline and 10-year radiographs with intraoral photographs of posterior implants from the narrow and wide keratinized mucosa groups.

Clinical and radiographic follow-up of implants in the narrow (NG) and wide (WG) groups over a 10-year period

Disease dynamics

The most valuable aspect of this study is the opportunity to see how the condition of the tissue around the implants changes not over a year or two, but over a whole decade.

What happened in the narrow group (NG, <2 mm)

  • Mucositis proved to be a chronic condition: in 58.4% of implants, it persisted from the beginning to the end of the observation period.

  • Only 15.3% returned to a state of health.

  • 6.2% progressed to peri-implantitis.

  • A total of 6.2% of implants remained healthy throughout the entire 10-year period.

What happened in the wide group (WG, ≥2 mm)

  • Mucositis also occurred, but less frequently: 39.2% of implants remained in this state.

  • In 23.6% of cases, health was successfully restored.

  • Peri-implantitis developed in only two implants (less than 4%).

  • 17.6% of implants maintained health throughout the entire observation period.

The big picture

  • Mucositis was the most common diagnosis in both groups, but in NG it occurred almost “by default.”

  • Peri-implantitis was rare, but more common in NG.

  • Tissue health in WG was preserved almost twice as often as in NG.

Visual comparison

Diagnosis after 10 years NG (<2 mm) WG (≥2 mm)
Healthy 21.5% 41.2%
Mucositis 72.3% 54.9%
Peri-implantitis 6.2% 3.9%

Thus, a narrow mucosa creates conditions for chronic inflammation, while a wide mucosa offers a chance for recovery and long-term health. For a practicing clinician, this means: The dynamics of peri-implant diseases directly depend on the millimeters of mucosa around the implant.

Interpretation and implications for practice

What do these data tell us when viewed through the eyes of a practicing clinician?

  • Narrow mucosa (<2 mm)

    • Leads to chronic mucositis: most implants remain in a state of inflammation.

    • Plaque, bleeding, and recession are recorded more frequently.

    • Marginal bone loss is more pronounced.

    • It is more difficult for the patient to maintain hygiene, although discomfort during brushing decreases over time.

  • Wide mucosa (≥2 mm)

    • Works as a natural “shield” for tissues.

    • The likelihood of being diagnosed with peri-implant disease is reduced by 84%.

    • Tissue health is maintained almost twice as often as in the narrow group.

    • Even with mucositis, there is a better chance of recovery.

  • Discomfort during brushing

    • At the beginning, patients with a narrow mucosa more frequently complained of discomfort.

    • After 10 years, the difference between the groups disappeared: discomfort decreased for everyone.

    • This confirms that the key risk factor is not the patient’s sensations, but objective indicators of plaque and inflammation.

What does this mean for the clinician?

  • Millimeters of mucosa around the implant are not a cosmetic detail, but a factor that determines the long-term fate of the restoration.

  • A narrow mucosa creates conditions for chronic inflammation and recession, even with regular care.

  • A wide mucosa increases the chances of tissue stability and health, reducing the risk of complications.

  • Discomfort during brushing is not the main indicator, but it can be an early sign of trouble.

Thus, the study shows: The width of keratinized mucosa is a predictor of long-term implant health. For a practicing clinician, this knowledge helps to better understand risks and predict treatment outcomes.

Conclusions

  • The width of the mucosa matters. A narrow keratinized mucosa (<2 mm) is associated with chronic mucositis, greater recession, and plaque accumulation. A wide keratinized mucosa (≥2 mm) reduces the risk of disease by 84% and more often preserves tissue health.

  • Mucositis is the main diagnosis. In both groups, peri-implant mucositis was the most common condition, but in the narrow group, it remained chronic in most implants.

  • Peri-implantitis is rare, but more common in cases of narrow mucosa. Over 10 years, it developed in 6.2% of implants in NG and only 3.9% in WG.

  • Discomfort during brushing does not determine the outcome. Patients eventually stop complaining, but objective indicators of inflammation and plaque remain key.

Some clinicians immediately opt for gingival plastic surgery if they see that the width of the attached keratinized gingiva is less than 2-3 mm. A properly performed procedure can even change the gingival biotype from thin to thick. However, this is beyond the scope of this article, and we are not qualified to make any recommendations.

We hope this material was especially useful for practicing professionals. Stay tuned for our next publications.

Disclaimer: Any medical or scientific information provided in connection with the content presented here makes no claim to completeness and the topicality, accuracy and balance of such information provided is not guaranteed. The information provided by Uniqa Dental Ltd. does not constitute medical advice or recommendation and is in no way a substitute for professional advice from a physician, dentist or other healthcare professional and must not be used as a basis for diagnosis or for selecting, starting, changing or stopping medical treatment. Physicians, dentists and other healthcare professionals are solely responsible for the individual medical assessment of each case and for their medical decisions, selection and application of diagnostic methods, medical protocols, treatments and products. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the content and information presented here. Products or treatments shown may not be available in all countries and different information may apply in different countries. For country-specific information please refer to our customer service or a distributor or partner of Uniqa Dental Ltd. in your region.
Curatorial Yurij
Curatorial Yurij
Head of Content at Uniqa Dental As an expert in dental industry, my task is to tell in a simple and fascinating way about complex highly organized series of procedures for the benefit of practitioners.