Why is this important?

The restoration emergence profile directly impacts the condition of the surrounding tissues. The smoother the angle, the less marginal bone loss occurs, and the more stable the soft tissue seal becomes. Moreover, the condition of the soft tissues is paramount: if the patient has sufficient attached gingiva and a high-quality soft tissue seal, even a 1–2 mm loss of marginal bone may not be clinically perceptible. However, statements and personal experience are not enough; therefore, we are sharing the results of a study by colleagues from Korea that you might find interesting.

The team set a goal to determine how the emergence profile and emergence angle influence the long-term prognosis of the restoration.

  • Emergence angle: This is the angle between the implant platform and the contour of the restoration.
  • It is hypothesized that excessively wide angles can impair soft tissue attachment, promote plaque accumulation, and consequently cause bone remodeling and increase the risk of peri-implantitis. The purpose of this study is to test the validity of these assumptions.

Study design

  • Model: A preclinical study on five young beagle dogs (split-mouth design). The dogs were fed a nutritionally balanced diet.
  • Implants: 30 implants placed in the mandibular premolar region. All surgical procedures were performed under general anesthesia.
  • Groups:
    • NE (Narrow Emergence angle) — Angle of 30°.
    • WE (Wide Emergence angle) — Angle of 60°.
  • Prosthetics: The implants were connected via splinted prostheses (three units). Before the study, oral prophylaxis was performed to maintain oral hygiene. One week after cleaning, bilateral mandibular premolars (P2, P3, P4) were extracted under general anesthesia. The premolars were hemisected with a diamond bur and then removed using elevators and forceps. After extraction, the sockets were carefully curetted and sutured with Monosyn 5/0 thread (B. Braun, Melsungen, Germany). The sutures were removed after one week. The illustration below shows the surgical procedure and follow-up images.
    Timeline diagram showing dental implant procedure stages from extraction through sacrifice over 11 months

    Timeline of the experimental procedure. Plaque control was performed from 1 week before extraction until sacrifice. The implant was placed 2 months after extraction. 2 months after implant placement, an intraoral scan was performed for the fabrication of the implant prosthesis. 3 months after implant placement, prostheses with wide and narrow emergence angles were attached. Radiographic imaging was performed at 0, 1, 3, and 6 months after prosthesis insertion. Subsequently, the animals were sacrificed, and tissue block samples were harvested.

    The process of tooth extraction, implant placement and prosthetics.

    Five-stage dental implant procedure showing tooth extraction, implant placement, healing abutments, and final prosthesis attachment

    Representative images of the surgical procedure. (a) Pre-extraction state. (b) Following the extraction of the mandibular second, third, and fourth premolars, crisscross sutures were performed. (c) 2 months after extraction, three implants were placed at the equicrestal level. (d) After healing abutments were connected, simple interrupted sutures were performed. (e) 3 months after implant placement, a splinted prosthesis was attached.

     

  • Analysis methods:
    • Radiography (0, 4, 12, 24 weeks after restoration)
    • Histomorphometric analysis
    • Circularly polarized light examination of collagen

    Radiographic, histomorphometric, and circularly polarized light microscopy analyses were performed by a single calibrated examiner (S. J. L.). To discern the differences attributable to the splinted position of the three implants, the analysis was segmented into three areas: the mesial or distal end of the terminal implant (T-end), the splinted zone of the terminal implant (T-splint), and the splinted zone of the middle implant (M-splint)

    Cross-sectional diagram showing three dental implants with splinted zones labeled as terminal and middle implant sections

    Splinting configuration. To examine the variations associated with the position of splinted implants, the implant areas were divided into three sections: the mesial or distal end of the terminal implant (T-end), the splinted zone of the terminal implant (T-splint), and the splinted zone of the middle implant (M-splint).

    Radiographs were taken immediately after implant placement (baseline) and then at 4, 12, and 24 weeks. For radiographic analysis, ImageJ software (National Institutes of Health, Bethesda, MD, USA) was used to measure crestal bone remodeling. This was defined as the distance from the implant platform to the most coronal point of bone-to-implant contact, observed from both the mesial and distal aspects of the implant. To correct for magnification errors, crestal bone remodeling was normalized as a percentage of the actual implant length. Crestal bone remodeling at each time point was corrected by calculating the difference from baseline. Additionally, bone remodeling levels were analyzed by classifying them as high (>0.5 mm) or low (≤0.5 mm) at 24 weeks after implant placement.

    Periapical radiographs showing dental implant marginal bone measurements at multiple time points with corresponding quantitative analysis graphs

    Marginal bone changes around implants in radiographic images. (a) Representative periapical radiographs following prosthesis connection. The distance from the implant platform (orange dotted line) to the bone-to-implant contact was measured at 0, 4, 12, and 24 weeks after prosthesis connection. Measurements were taken on periapical radiographs at the mesial (red line) and distal (blue line) sites. (b) Radiographic analysis of marginal bone loss from baseline (0-week) to 4, 12, and 24 weeks. NE, narrow emergence angle; WE, wide emergence angle; T-end, the mesial or distal end of the terminal implant; T-splint, the splinted zone of the terminal implant; M-splint, the splinted zone of the middle implant. *p < 0.05; **p < 0.01.

    Vertical measurements were performed on non-decalcified, hematoxylin and eosin-stained specimens using CaseViewer software. Consistent with previous studies (Valles et al. 2018), five anatomical landmarks were identified: the peri-implant mucosal margin (PM), the apical extent of the junctional epithelium (aJE), the implant shoulder (IS), the bone crest (BC), and the first bone-to-implant contact (fBIC). Measurements were performed for six distances: from IS to fBIC, from IS to BC, from PM to aJE, from aJE to fBIC, from PM to fBIC, and from IS to PM. In addition, the area of infiltrated connective tissue (ICT) was quantified.

    Histological comparison showing dental implant tissue integration with narrow and wide emergence angles highlighting bone contact

    Representative images of histomorphometric analysis. The left image represents the narrow emergence angle group, and the right image represents the wide emergence angle group. aJE, apical extension of junctional epithelium; BC, bone crest; fBIC, first bone-to-implant contact; ICT, infiltrated connective tissue; IS, implant shoulder; PM, peri-implant mucosa.

    Analysis using circularly polarized light microscopy.

    Undecalcified specimens stained with picrosirius red were examined using a circular polarizing microscope. Images were captured at ×40 magnification using a microscope camera. The images were analyzed by dividing them into five regions: oral epithelium (OE), oral connective tissue (OCT), peri-implant sulcular epithelium (PISE), peri-implant epithelium (PIE), and peri-implant infiltrated connective tissue (PICT) (Ikeda et al. 2000). For quantitative analysis of collagen fibers, shade identification of collagen fibers (2–256) was used (Ko et al. 2024, 2023; Rich and Whittaker 2017). The area occupied by collagen fibers was measured and calculated as a proportion of the total area.

    Polarized light microscopy image showing dental implant tissue regions with box plots comparing collagen fiber percentages

    Quantitative assessment of collagen fibers in circularly polarized light microscopy images. (a) A representative microscopy image of the soft and hard tissues surrounding the implant. (b) Analysis of circularly polarized light microscopy comparing the narrow and wide emergence groups (b) and different split positions (c). OE, oral epithelium; OCT, oral connective tissue; PIE, peri-implant epithelium; PISE, peri-implant sulcular epithelium; PICT, peri-implant infiltrated connective tissue; I, implant; B, alveolar bone; NE, narrow emergence angle; WE, wide emergence angle; T-end, the mesial or distal end of the terminal implant; T-splint, the splinted zone of the terminal implant; M-splint, the splinted zone of the middle implant. *p < 0.05; **p < 0.01; ***p < 0.001.

Results

Table and heatmap comparing bone remodeling levels across different splinting configurations and emergence angles in dental implants

1. Radiographic data

  • In the WE group, more pronounced bone remodeling was observed.
  • After 24 weeks:
    • T-end: 0.90 mm (WE) vs. 0.12 mm (NE).
    • T-splint: 1.4 mm (WE) vs. 0.57 mm (NE).
    • M-splint: 1.03 mm (WE) vs. 0.61 mm (NE).

Conclusion: A wide emergence angle is associated with greater bone loss, especially in the area of splinted implants.

2. Histological data

  • NE (30°): Thin epithelial layer, dense connective tissue attachment, minimal inflammation.
  • WE (60°): Thickening of the epithelium, inflammatory cell infiltration, plaque accumulation, compromised connective tissue attachment.

3. Collagen fibers

  • In the WE group, the area of collagen fibers in the peri-implant epithelium and connective tissue was significantly smaller.
  • This indicates a weaker soft tissue barrier.

Table: Comparison of NE and WE

Parameter NE (30°) WE (60°)
Bone remodeling (24 weeks) ≤0.6 mm ≥1.0 mm
Attachment of connective tissue Long, dense Short, intermittent
Epithelium Thin Thickened
Collagen More Less
Inflammation Minimal Pronounced

Study results diagram.

Flowchart comparing dental implant emergence angles showing narrow 30 degree, splinted configuration, and wide 60 degree outcomes

Practical conclusions

  1. Wide emergence angle (60°) may:
    • Impair soft tissue attachment
    • Promote plaque accumulation
    • Cause more pronounced bone remodeling
  2. Narrow emergence angle (30°) provides:
    • Better formation of the soft tissue barrier
    • Less bone loss
    • More stable long-term results
  3. Clinical recommendations:
    • When designing a prosthesis, strive for a narrower emergence angle
    • Account for risks associated with splinted structures, especially for the middle implant
    • Pay close attention to hygiene in the splinted area where access is limited.

Conclusion

The study by Seung-Ju Lee et al. convincingly demonstrated that a wide restoration emergence angle (60°) negatively affects the soft and hard tissues around splinted implants. For the clinician, this highlights the need for careful selection of prosthetic parameters and an emphasis on biocompatible contours.

Source

Seung-Ju Lee, Yuseung Yi, Frank Schwarz, Jungwon Lee, Ki-Tae Koo. The Effect of Restorative Emergence Angle on Soft and Hard Tissue Around Splinted Implants: A Preclinical Study. Clinical Oral Implants Research, 2025; 36:1603–1613. DOI: 10.1111/clr.70035.

Disclaimer: Any medical or scientific information provided in connection with the content presented here makes no claim to completeness and the topicality, accuracy and balance of such information provided is not guaranteed. The information provided by Uniqa Dental Ltd. does not constitute medical advice or recommendation and is in no way a substitute for professional advice from a physician, dentist or other healthcare professional and must not be used as a basis for diagnosis or for selecting, starting, changing or stopping medical treatment. Physicians, dentists and other healthcare professionals are solely responsible for the individual medical assessment of each case and for their medical decisions, selection and application of diagnostic methods, medical protocols, treatments and products. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the content and information presented here. Products or treatments shown may not be available in all countries and different information may apply in different countries. For country-specific information please refer to our customer service or a distributor or partner of Uniqa Dental Ltd. in your region.
Curatorial Yurij
Curatorial Yurij
Head of Content at Uniqa Dental As an expert in dental industry, my task is to tell in a simple and fascinating way about complex highly organized series of procedures for the benefit of practitioners.